            Induction Heating Equipment
              Fluid Damped Single Point Load Cell
                        High Capacity Off Center Single Point Load Cell
Description:

Model FDM11 is specifically designed to be used where fast acquisition of a stable load signal is recquired. The model FDM11’s unique fluid damping system allows the loadcell to be used in applications that previously required the use of LVDT’s or similar types of measuring devices. The model FDM11 brings load cell adaptability into check weighing and grading applications. Sealed to IP66 level and available in coated steel or stainless steel, the model FDM11 is suitable for most wash-down applications.

                        High Capacity Off Center Single Point Load Cell
                        High Capacity Off Center Single Point Load Cell
Application:

• Multi-head filling machines
• Check weighing
• Grading machines
• Liquid filling
• Dynamic weighing

Features:

• Capacities 2 - 50kg
• Painted steel construction
• IP66 protection
• Available with metric and UNC threads

Optional Features :

• Stainless steel construction
• Digital version available

Parameter Value Unit
Rated Output-R.o. 2 + mV/V
Rated Output Tolerance 0.2 + mV/V
Zero balance 0.1 +mV/V
Zero Return, 30 min. 0.030 +% of applied Load
Total Error 0.030 +% of rated output
Temperature Effect On Zero 0.0025 +% of rated output/ C
Temperature effect on output, unbalanced 0.00810 +% of Load/ C
Temperature Range, Compensated -10 to +40 C
Temperature Range, Safe -20 to +70 C
Maximum Safe Central Load 150 % of R.C.
Ultimate central overload 200 % of R.C.
Excitation, recommended 10 Vdc or Vac rms
Excitation, maximum 15 Vdc or Vac rms
Input Impedance 415+15 ohms
Output impedance 350+3 ohms
Insulation Resistance >1000 mega-ohms
Cable Length 15 meter
Cable Type 4 Wire  
Construction Stainless steel  